Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
SICOT J ; 3: 19, 2017.
Article in English | MEDLINE | ID: mdl-29785927

ABSTRACT

INTRODUCTION: Femoral/tibial lengthening with a telescopic, magnetically-powered, intramedullary nail is an alternative to lengthening with external fixation. METHODS: Pre-clinical testing was conducted of the PRECICE in a human cadaver. A retrospective review of the first 30 consecutive patients who underwent unilateral lengthening was also conducted. Nail accuracy was obtained by comparing the amount of nail distraction to the final bone length achieved at the end of the distraction process. Relative standard deviation of accuracy was used to calculate nail precision. RESULTS: Devices performed successfully in a human cadaver. Thirty consecutive patients (10 females, 20 males; mean age, 23 years) with limb length discrepancy (LLD) were followed an average of 19 months (range, 12-24 months). Etiology included congenital shortening (14), posttraumatic deformities (7), Ollier disease (3), osteosarcoma resection (1), prior clubfoot (2), hip dysplasia (1), post-septic growth arrest of knee (1), and LLD after hip arthroplasty (1). Twenty-four femoral and eight tibial nails were implanted. Mean preoperative lengthening goal was 4.4 cm (range, 2-6.5 cm); mean postoperative length achieved was 4.3 cm (range, 1.5-6.5 cm). Average consolidation index was 36.4 days/cm (range, 12.8-113 days/cm). Mean nail accuracy was 97.3% with a precision of 92.4%. Average preoperative and 12-month postoperative Enneking scores were 21.5 and 25.3 (p < 0.001), respectively. The preoperative and 12-month postoperative SF-12 physical and mental component scores were not statistically different. Nine complications (nine limb segments) resolved: two partial femoral unions, two suspected deep vein thrombosis (DVT), one delayed tibial union, one fibular nonunion, one peroneal nerve irritation, one knee joint subluxation, and one confirmed DVT. Twenty-nine (91%) of 32 limb segments achieved successful bone healing without revision surgery. DISCUSSION: Limb lengthening with PRECICE is reliable, but larger trials with longer follow-up will reveal limitations. Implantable nails prevent problems associated with external fixation, such as muscle tethering and pin-site infections.

2.
J Long Term Eff Med Implants ; 26(2): 173-181, 2016.
Article in English | MEDLINE | ID: mdl-28094742

ABSTRACT

Nerve injury is a serious potential complication associated with clinical use of tourniquets during surgery. A novel narrow, single-use silicon ring tourniquet has been introduced, which may cause less nerve compression and provide a larger field of surgical exposure than standard wide tourniquets. We investigated both types of tourniquets in the non-dominant proximal upper arm of 15 healthy human volunteers. Pain and neurological effects were assessed during 15 minute trials with each tourniquet applied 1 week apart without anesthesia according to the manufacturers' recommendations. Median nerve function was studied using the pressure-specified sensory device, an instrumented two-point discriminator, and pain was assessed by two validated instruments. Skin sores, redness, nerve damage, or neurological complications did not occur in either group. Subjects reported more pain with the narrow tourniquet; however, measurable effect on median nerve function was the same in both groups. Tourniquet application with the narrow device was more efficient, the device was easier to use, and larger surgical field exposure was obtained. We conclude that the sensory deficit with the use of narrow tourniquets is not greater than that observed with pneumatic/wide tourniquets.


Subject(s)
Arm/physiopathology , Median Nerve/physiopathology , Pain/etiology , Tourniquets , Female , Healthy Volunteers , Humans , Male , Pain Measurement
3.
J Surg Orthop Adv ; 24(3): 174-9, 2015.
Article in English | MEDLINE | ID: mdl-26688988

ABSTRACT

External fixation has long been used for limb lengthening but can result in many complications, such as tethering of the soft tissues, pain, decreased joint motion, scarring, and nerve injury. Recently, a controllable, telescopic, internal lengthening nail was developed to address many of these issues and hopefully improve the overall experience for the patient. The satisfaction rates of internal and external fixation for limb lengthening were compared in 16 patients, all of whom have experienced both methods. Thirteen out of 16 patients responded to a limb-lengthening questionnaire, developed by the authors for this patient population. Patients preferred the internal device with respect to overall satisfaction, reduced pain, ease of physical therapy, and better cosmetic appearance. When asked which device they would prefer if another surgery was required, all patients chose the internal device. From the patients' perspective, the internal lengthening device is an improvement over the traditional external fixator.


Subject(s)
Bone Diseases, Developmental/surgery , Bone Lengthening/instrumentation , External Fixators , Femur/surgery , Growth Disorders/surgery , Internal Fixators , Patient Satisfaction , Achondroplasia/surgery , Adolescent , Bone Lengthening/methods , Child , Child, Preschool , Cohort Studies , Ectromelia/surgery , Enchondromatosis/surgery , Female , Femur/abnormalities , Humans , Male , Retrospective Studies , Surveys and Questionnaires
4.
Orthopedics ; 37(12): e1049-57, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25437077

ABSTRACT

The authors compared the results of treating nonunion with either bone morphogenetic protein (BMP)-7 or BMP-2. Between 2001 and 2009, 214 limb segments were treated for nonunion with either BMP-7 or BMP-2 at the authors' institution. Sixty-three subjects received 76 units of BMP-7. Radiographic healing occurred in 70% of limb segments at an average of 30 weeks after surgery, and 75% of limb segments were weight bearing at an average of 23 weeks after surgery. In 15.8%, persistent nonunion necessitated additional surgery. Average follow-up was 32 months. One hundred twelve subjects received 138 units of BMP-2. Radiographic healing occurred in 93% of limb segments at an average of 19 weeks after surgery, and 88% were weight bearing at an average of 15 weeks after surgery. In 6.25%, persistent nonunion necessitated additional surgery. Average follow-up was 17 months. Several significant differences were observed. Patients in both BMP-7 and BMP-2 groups were able to fully weight bear at an average of 23 and 15 weeks, respectively (P<.001). Further, both BMP-7 and BMP-2 groups healed at an average of 30 and 19 weeks, respectively (P<.001). Additionally, healing occurred in more limb segments in the BMP-2 group (93%) than in the BMP-7 group (70%) (P<.001). No difference in the complication rate was seen between groups. Patients who received BMP-2 for the treatment of nonunion had a higher rate of radiographic healing, achieved radiographic healing more quickly, and were able to bear weight sooner than those who underwent treatment with BMP-7.


Subject(s)
Bone Morphogenetic Protein 2/therapeutic use , Bone Morphogenetic Protein 7/therapeutic use , Femoral Fractures/drug therapy , Fractures, Ununited/drug therapy , Humeral Fractures/drug therapy , Tibial Fractures/drug therapy , Adolescent , Adult , Aged , Child , Child, Preschool , Female , Femoral Fractures/physiopathology , Fracture Healing/drug effects , Fractures, Ununited/physiopathology , Humans , Humeral Fractures/physiopathology , Male , Middle Aged , Tibial Fractures/physiopathology , Weight-Bearing , Young Adult
5.
World J Orthop ; 5(5): 585-90, 2014 Nov 18.
Article in English | MEDLINE | ID: mdl-25405086

ABSTRACT

The Ponseti method has become the gold standard for the treatment of idiopathic clubfoot. Its safety and efficacy has been demonstrated extensively in the literature, leading to increased use around the world over the last two decades. This has been demonstrated by the increase in Ponseti related PubMed publications from many countries. We found evidence of Ponseti activity in 113 of 193 United Nations members. The contribution of many organizations which provide resources to healthcare practitioners in low and middle income countries, as well as Ponseti champions and modern communication technology, have helped to spread the Ponseti method around the world. Despite this, there are many countries where the Ponseti method is not being used, as well as many large countries in which the extent of activity is unknown. With its low rate of complication, low cost, and high effectiveness, this method has unlimited potential to treat clubfoot in both developed and undeveloped countries. Our listing of countries who have not yet shown presence of Ponseti activity will help non-governmental organizations to target those countries which still need the most help.

6.
Orthopedics ; 37(9): e796-803, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25350622

ABSTRACT

The effectiveness of using the Reamer/Irrigator/Aspirator (RIA) System (Synthes, Inc, West Chester, Pennsylvania) to obtain bone graft from the intramedullary canal of long bones for the treatment of bone defects and nonunions has been previously documented. However, there is nothing in the literature discussing the potential for reaming the same canal at subsequent surgeries. The authors detail their experience of 8 instances of sequential reaming in 7 patients. Six patients were harvested twice, and 1 patient was harvested 3 times. In each patient, the bone graft was obtained from the same canal. The main outcome measurements were time interval between reamings, reamer head size, indication for reaming, volume of harvested bone graft, and complications. Average volume of graft obtained in the first reaming procedure was 34 mL (range, 25-50 mL). After an average of 9 months (range, 3-16 months), the subsequent reaming was performed. Average volume of graft obtained in the second procedure was 45 mL (range, 28-65 mL). In the authors' series, no reaming-related complications were observed. The graft volume was the same or increased during the subsequent intramedullary reaming in all but 1 case, suggesting that the intramedullary canal is a potentially renewable source for bone graft. There were no complications related to the sequential reaming procedure. Overall, the authors' data suggest that sequential reaming with the RIA has the potential to safely and effectively provide a large quantity of bone graft on multiple occasions.


Subject(s)
Bone Diseases/surgery , Bone Resorption/surgery , Bone Transplantation/methods , Femur/transplantation , Fractures, Bone/surgery , Tissue and Organ Harvesting/instrumentation , Adolescent , Adult , Aged , Female , Fractures, Bone/complications , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
7.
Orthopedics ; 37(2): 101-6, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24679191

ABSTRACT

Limb-length discrepancy after total hip arthroplasty (THA) leads to patient dissatisfaction and can be a cause of orthopedic surgery malpractice cases. Nonsurgical and surgical techniques exist to correct limb-length discrepancies. Two limb-lengthening methods were used to correct greater than 2-cm limb-length discrepancies after THA: lengthening over a femoral nail with an external fixator and lengthening with an intramedullary kinetic skeletal distractor. These techniques achieved equal length in less than 4 weeks, with both resulting in a healed distraction gap within 4 months. No patient had loss of proximal or distal joint motion, and mean Harris Hip Score was 90 points at final follow-up. No surgical complications were reported with the intramedullary skeletal kinetic distractor. Limb lengthening using an intramedullary skeletal kinetic distractor is a viable treatment option resulting in reliable lengthening, healing of the distraction gap, and progression to full weight bearing.


Subject(s)
Algorithms , Arthroplasty, Replacement, Hip/adverse effects , Fracture Fixation, Intramedullary/instrumentation , Leg Length Inequality/etiology , Leg Length Inequality/therapy , Osteogenesis, Distraction/instrumentation , Plastic Surgery Procedures/instrumentation , Female , Humans , Middle Aged , Osteogenesis, Distraction/methods , Prosthesis Design , Plastic Surgery Procedures/methods , Treatment Outcome
8.
Clin Orthop Relat Res ; 472(12): 3860-8, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24664194

ABSTRACT

BACKGROUND: Patients with congenital limb shortening can present with joint instability, soft tissue contractures, and significant leg length discrepancy. Classically, lengthening is done with external fixation, which can result in scarring, pin site infection, loss of motion, and pain. We therefore developed an alternative to this approach, a new, controllable, internal lengthening device for patients with congenital limb shortening. QUESTIONS/PURPOSES: We evaluated this device in terms of (1) healing index, (2) complications, (3) accuracy of the device's external controller, and (4) adjacent-joint ROM. METHODS: Between January 2012 and May 2013, we treated 66 patients for congenital limb shortening, of whom 21 were treated using this device. During this period, general indications for using the device were patients with leg length discrepancies of 2 cm or more, with intramedullary canals able to withstand rods of at least 12.5-mm diameter and 230-mm length, without active infection in the affected bone, able to comply with the need for frequent lengthening, and without metal allergies or an implanted pacemaker. We included only those patients who had completed their course of treatment and were currently fully weightbearing, leaving 18 patients (21 bone segments) available for followup at a minimum of 6 months after limb lengthening (mean, 14 months; range, 6-22 months). Mean age was 19 years (range, 9-49 years). Sixteen femurs and five tibias were lengthened a mean of 4.4 cm (range, 2.1-6.5 cm). Mean distraction index was 1.0 mm/day (range, 0.5-1.8 mm/day). Healing index, complications, device accuracy, and ROM were recorded. To date, 10 of the 21 devices have been removed. This was typically done 12-24 months after insertion when the bone was solidly healed on all four cortices. RESULTS: Mean healing index was 0.91 months/cm (range, 0.2-2.0 months/cm). There were seven complications requiring an additional unplanned surgery, including one hip flexion contracture, three femurs with delayed healing, one tibia with delayed healing, one hip subluxation/dislocation, and one knee subluxation. The external controller was accurate as programmed and actual lengthening amounts were consistent. ROMs of the hip, knee, and ankle were essentially maintained. CONCLUSIONS: This device is completely internal, allowing for satisfactory joint motion during treatment in most patients. Lengthening was achieved in an accurate, controlled manner, and all patients reached their goal length. Complications remain a concern, as is the case with all approaches to this complex patient population. Both future comparative studies and longer-term followup are needed. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Bone Lengthening/instrumentation , Bone Nails , Ectromelia/surgery , Femur/surgery , Fibula/surgery , Leg Length Inequality/surgery , Adolescent , Adult , Ankle Joint/physiopathology , Biomechanical Phenomena , Bone Lengthening/adverse effects , Child , Ectromelia/diagnosis , Ectromelia/physiopathology , Female , Femur/abnormalities , Femur/diagnostic imaging , Femur/physiopathology , Fibula/abnormalities , Fibula/diagnostic imaging , Fibula/physiopathology , Humans , Knee Joint/physiopathology , Leg Length Inequality/congenital , Leg Length Inequality/diagnosis , Leg Length Inequality/physiopathology , Male , Middle Aged , Prospective Studies , Prosthesis Design , Radiography , Range of Motion, Articular , Time Factors , Treatment Outcome , Weight-Bearing , Wound Healing , Young Adult
9.
J Pediatr Orthop ; 30(6): 594-7, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20733426

ABSTRACT

BACKGROUND: For decades, the Blount staple has been used to perform temporary hemiepiphysiodesis for angular deformity correction in children with open growth plates. Recently, the eight-PlateGuided Growth System (Orthofix, McKinney, TX) has gained popularity for use in this procedure. The eight-Plate is said to be superior to the Blount staple, as it is less likely to break or migrate out of the bone. However, some centers have observed mechanical failures of the eight-Plate cannulated screws. METHODS: The purpose of our study was to conduct a multicenter survey to determine which factors increase the risk of mechanical failure with this device. We distributed a questionnaire in 2007 to 841 members of the Pediatric Orthopaedic Society of North America that asked about their experience with the eight-Plate and whether they had observed any mechanical failures. Follow-up surveys were distributed to determine the background of the failed cases. RESULTS: Of the 445 (53%) surgeons who responded, 314 (71%) reported that they use the eight-Plate in their practice. Forty-eight (15%) of the 314 surgeons who use the eight-Plate observed a total of 65 cases of mechanical failure. In every case, the screws failed, not the plate. The average body mass index of these patients was 37.8 kg/m (range, 19.2 to 70.2 kg/m). CONCLUSIONS: Overweight and obese patients with Blount disease were among those most likely to experience eight-Plate screw failure. Fractures occurred almost always in the metaphyseal screw-not where the head meets the shank but where the shank enters the lateral cortex, presumably because of 3-point bending. No broken plates were reported. In high-risk cases, we now consider using 2 parallel eight-Plates or using solid (not cannulated) screws for plate fixation. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Bone Screws , Equipment Failure , Growth Plate/surgery , Orthopedic Procedures/methods , Adolescent , Adult , Bone Diseases, Developmental/complications , Bone Plates , Child , Child, Preschool , Epiphyses/abnormalities , Epiphyses/surgery , Female , Follow-Up Studies , Growth Plate/abnormalities , Humans , Knee Joint/abnormalities , Knee Joint/surgery , Male , Obesity/complications , Osteochondrosis/complications , Osteochondrosis/congenital , Overweight/complications , Risk Factors , Surgical Stapling/methods , Surveys and Questionnaires , Young Adult
10.
Clin Orthop Relat Res ; 466(12): 3003-10, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18800215

ABSTRACT

UNLABELLED: Between 2003 and 2006, we used an extraarticular, cannulated, fully threaded posterior calcaneotibial screw to prevent equinus contracture in 10 patients (four male and six female patients, 14 limbs) undergoing tibial lengthening with the intramedullary skeletal kinetic distractor. Diagnoses were fibular hemimelia (two), mesomelic dwarfism (two), posteromedial bow (one), hemihypertrophy (one), poliomyelitis (one), achondroplasia (one), posttraumatic limb-length discrepancy (one), and hypochondroplasia (one). Average age was 24.5 years (range, 15-54 years). The screw (length, typically 125 mm; diameter, 7 mm) was inserted with the ankle in 10 degrees dorsiflexion. Gastrocnemius soleus recession was performed in two patients to achieve 10 degrees dorsiflexion. Average lengthening was 4.9 cm (range, 3-7 cm). Screws were removed after a mean 3.3 months (range, 2-6 months). Preoperative ankle range of motion was regained within 6 months of screw removal. No neurovascular complications were encountered, and no patients experienced equinus contracture. We also conducted a cadaveric study in which one surgeon inserted screws in eight cadaveric legs under image intensifier control. The flexor hallucis longus muscle belly was the closest anatomic structure noted during dissection. The screw should be inserted obliquely from upper lateral edge of the calcaneus and aimed lateral in the tibia to avoid the flexor hallucis longus muscle. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Subject(s)
Ankle Joint , Bone Lengthening , Equinus Deformity/prevention & control , Osteogenesis, Distraction , Adolescent , Adult , Bone Screws , Calcaneus/surgery , Ectromelia/surgery , Female , Humans , Male , Middle Aged , Postoperative Complications/prevention & control , Tibia/surgery
11.
Foot Ankle Clin ; 13(3): 471-84, ix, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18692010

ABSTRACT

Ankle joint distraction has been shown to be a viable alternative to ankle arthrodesis or ankle replacement. The à la carte approach to ankle joint preservation (resection of blocking osteophytes, release of muscle/joint contractures, and realignment osseous ankle procedures) presented in this article as important for a successful outcome as is the hinged ankle joint distraction technique itself. The authors reviewed 32 patients who underwent this ankle joint distraction technique and found 78% of patients had maintained their ankle range of motion and have no pain to occasional moderate pain that can be managed generally with nonsteroidal anti-inflammatory drugs alone. Only one has required an ankle fusion, and only one has been converted to an ankle joint replacement. The longevity of these results and the higher percent of good or excellent results when compared with other studies suggest that combining adjunctive procedures and articulation with ankle distraction improves the results of this procedure.


Subject(s)
Ankle Joint/surgery , Arthroplasty/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...